Different types of
Induction Motor
SINGLE PHASE INDUCTION MOTOR
1.
Split phase induction motor
There are various
types of self-starting motors, known as split phase motors. Such motors have a
starting winding displaced 90 electrical degrees from the main or running
winding. In some types, the starting winding has a fairly high resistance,
which causes the current in this...
Why LT motors are delta connected and HT motors are star connected?
Why LT motors are delta connected and HT motors are star connected?There is both reason technical and commercial.
1. In star, phase current is same as line current. But phase voltage is 1/1.732 times line voltage. So insulation required in case of HT motor is less.
2. The starting current for motors is 6 to 7 times full load current. So start-up...
Brief Idea of Induction Motor

Brief Idea of Induction MotorInduction motor: is an energy conversion device that converts electrical energy into useful rotational kinetic energy, it is an application of the Faraday's law of induction.
Sectional View
3-ph Induction Motor
Drawing of Induction Motor
Induction motor are...
Air Insulated Switch-gear VS Gas Insulated Switch-gear

Air Insulated Switch-gear VS Gas Insulated Switch-gear
Gas Insulated Switch-Gear
Air Insulated Switch-Gear
Limitations of Air Insulated Switchgears (AISs)Large dimensions due to statutory clearances & poor dielectric strength of air
Insulation deterioration with ambient conditions and susceptibility...
Every Challenge Is An Opportunity

Edison, one of Europe’s oldest power companies, which was founded in 1884 in Milano, owns the Fontanamora hydroelectric plant that generates three megawatts (MW) of renewable power from turbines and auxiliary machinery. The plant is situated at Lombardy by a fast-flowing river at the bottom of a steep...
RENEWABLE ENERGY DEMAND IN EUROPE REACHES RECORD LEVELS

RENEWABLE ENERGY DEMAND IN EUROPE REACHES RECORD LEVELS
The demand for renewable electricity in Europe, documented with Guarantees of Origin (GO), continued to grow in 2015. The growth is up more than 8% from 2014 and surpassed 340 TWh. Behind this growth are thousands of businesses and millions of...
Why Transformer Rating In kVA, Not in KW?
Why Transformer Rating In kVA, Not in KW?In Simple words,
There are two type of losses in a transformer:
1. Copper Losses2. Iron Losses or Core Losses or Insulation LossesCopper losses ( I²R)depends on Current which passing through transformer winding while Iron Losses or Core Losses or Insulation Losses depends on Voltage.
That’s why the Transformer Rating may be expressed in...
Popular Posts
-
Switchboard Panel The Switchboard Design Requirements Design Rules The following rules of design have to be implement in the aim t...
-
PSIM Software PSIM Software PSIM is one of the fastest simulators for power electronics simulation . It achieves fast simulation ...
-
Different Parts of Transformer 1. Oil filter valve 17. Oil drain valve 2. Conservator 18. Jacking boss ...
-
Different types of transformer Types of Transformers: There are two basic Types of Transformers Single Phase Transformer Three Phase Transf...
-
Transformer Working principle of Transformer Transformer works on the principle of mutual induction of two coils or Faraday Law’s Of...
-
Introduction to Electrical Transformer What is a Transformer? In Very Simple words. Transformer is a device which: Transfer Electr...
-
Definition of Switchgear A switchgear or electrical switchgear is a generic term which includes all the switching devices associated wit...
-
How to Wire a Switch and a Load (a Light Bulb) to an Electrical Supply? As can be seen in the diagram the wiring is pretty simple. ...
-
Basic Refrigeration Cycle Principles of Refrigeration Liquids absorb heat when changed from liquid to gas Gases give off heat whe...
-
Quick guide Residential wiring diagrams, Codes, And Symbols This book is about Residential wiring diagrams, Codes, And Symbols. From t...